MX6 Multi Gas Detector | Portable Gas Monitor for Up to Six Gases

MX6 iBrid Gas Detector for Multiple Gases

Get ready to see hazardous levels of oxygen, toxic and combustible gas, and volatile organic compounds (VOCs) like never before.

  • 1-6 Gas monitor
  • Full-color LCD display
  • 24 Sensor options including PID and IR
  • iNet™ Ready and Docking Station™ compatible

Get ready to see hazardous levels of oxygen, toxic and combustible gas, and volatile organic compounds (VOCs) like never before. The MX6 iBrid™ is more than an intelligent hybrid of Industrial Scientific's best monitoring technologies. It's the first gas monitor to feature a full-color LCD display screen. 

The display improves safety with clear readings in low light, bright light or anywhere in between. Whether the work is outside, inside or underground, it's easy to see what gas hazards lurk in the immediate work environment. And a color display is more than eye-catching. It allows the user to step through instrument settings and functions with an intuitive menu and the instrument's five-way navigation button. It even supports the option of on-board graphing for easily interpreted direct readings and recorded data. 

Plus, the MX6 iBrid is our most rugged instrument ever. It carries a lifetime warranty and is fully compatible with our DS2 Docking Station™iNet DS   and iNet™ Instrument Network

Specifications

Instrument Warranty:

Warranted for as long as the instrument is supported by
Industrial Scientific Corporation

Case Material:

Lexan/ABS/Stainless Steel w/protective rubber overmold

Dimensions:

135 mm x 77 mm x 43 mm (5.3" x 3.05" x 1.7") - without pump
167 mm x 77 mm x 56 mm (6.6" x 3.1" x 2.2") - with pump

Weight:

409 g (14.4 oz) typical - without pump; 511 g (18.0 oz) typical - with pump

Display/Readout:

Color Graphic Liquid Crystal Display

Power Source/Run Times:

Rechargeable Lithium-ion (Li-ion) Battery Pack (24 hours) - without pump

Rechargeable, Extended-Range Lithium-ion (Li-ion) Battery Pack

(36 hours) - without pump

Replaceable AA Alkaline Battery Pack (10.5 hours) - without pump

Operating Temperature Range:

-20ºC to 55ºC (-4ºF to 131ºF)

Operating Humidity Range:

15% to 95% non-condensing (continuous)

Measuring ranges:

Sensor

Range

Resolution

Catalytic Bead

Combustible Gas

0-100% LEL

1%

Methane

0-5% vol

0.01%

Electrochemical

Ammonia

0-500 ppm

1

Carbon Monoxide

0-1,500 ppm

1

Carbon Monoxide (High Range)

0-9,999 ppm

1

Carbon Monoxide/Hydrogen low

0-1,500 ppm

1

Chlorine

0-50 ppm

0.1

Chlorine Dioxide

0-1 ppm

0.01

Carbon Monoxide/

Hydrogen Sulfide (COSH)

CO: 0-1,500 ppm

H2S: 0-500 ppm

1

0.1

Hydrogen

0-2,000 ppm

1

Hydrogen Chloride

0-30 ppm

0.1

Hydrogen Cyanide

0-30 ppm

0.1

Hydrogen Sulfide

0-500 ppm

0.1

Nitric Oxide

0-1,000 ppm

1

Nitrogen Dioxide

0-150 ppm

0.1

Oxygen

0-30% vol

0.1%

Phosphine

0-5 ppm

0.01

Phosphine (High Range)

0-1,000 ppm

1

Sulfur Dioxide

0-150 ppm

0.1

Infrared

Hydrocarbons

0-100% LEL

1%

Methane (% vol)

0-100% vol

1%

Methane (% LEL)

0-100% LEL

1%

Carbon Dioxide

0-5% vol

0.01%

Photoionization

VOC

0-2,000 ppm

0.1

Certifications:

UL

Class I, Groups A,B,C,D T4; Class II, Groups F,G; AEx ia d IIC T4

CSA

Class I, Groups A,B,C,D T4; Ex d ia IIC T4

MSHA

CFR30, Part 22, Intrinsically safe for methane/air mixtures

ATEX

Ex ia IIC T4 Ga / Ex ia I Ma; IP64
Equipment Group and Category: II 1G / I M1 (I M2 w/IR sensor)

IECEx

Ex ia IIC T4 Ga / Ex ia I (Ex ia d I w/IR sensor)

ANZEx

Ex ia s Zone 0 I, IP64 Asp., IP64 Dif. Ex ia s Zone 0 IIC T4

INMETRO

Ex ia IIC T4 Ga

GOST-R

PBExiadI X / 1ExiadIICT4 X

KOSHA

Ex d ia IIC T4

China Ex

Ex ia d I/IIC T4

China CPC

Metrology Approval

* These specifications are based on performance averages and may vary by instrument


BASE INSTRUMENTSENSORS
OPTIONS
BATTERY
OPTIONS
VERSION
OPTIONS
LANGUAGE OPTIONS

MX6 iBrid Logo

Supplied with Monitor:
universal charger, nylon carrying case, belt clip, calibration cup, wrist strap, maintenance tool, manual, quick start guide, calibration tubing, dust filter/water stop (aspirated), calibration fitting (aspirated), sample tubing (aspirated).
Combustible Gases:
LEL (Pentane) LEL (Methane)
CH 4 IR (0-100% vol.) CH 4 (0-5%)
Hydrocarbons IR (0-100% LEL)

Volatile Organic Compounds: PID

Toxic Gases:
H 2 S, O 2 , NO 2 , CO, CO/H 2 S,
NH 3 , Cl 2 , ClO 2 , PH 3 , CO High,
SO 2 , HCl, HCN, H 2 , PH 3 High,
NO, CO/H 2 low interference, CO 2 IR
Li-ionDiffusionEnglish
Li-ion/Ext. RangePumpFrench
Alkaline Spanish
Li-ion MSHA/AUS German
Li-ion/Ext. Range MSHA/AUS Italian
Alkaline MSHA/AUS Dutch
Li-ion GOST Portuguese
Li-ion/Ext. Range GOST Indonesian
Alkaline GOST Russian
  Polish
  Czech

 

 

MOST COMMON INSTRUMENT CONFIGURATIONS for (UL/CSA)
PART NO.DESCRIPTION
MX6-K1230101MX6 - LEL, CO, H2S, O2, Li-ion
MX6-K0230101MX6 - LEL, H2S, O2, Li-ion
MX6-K1030101MX6 - LEL, CO, O2, Li-ion
MX6-K0030101MX6 - LEL, O2, Li-ion
MX6-K123R211MX6 - LEL, CO, H2S, O2, PID, Ext. Li-ion, Pump
MX6-K1235101MX6 - LEL, CO, H2S, O2, SO2, Li-ion
MX6-K0235101MX6 - LEL, H2S, O2, SO2, Li-ion
MX6-0000R211MX6 - PID, Ext. Li-ion, Pump
COMMON INDUSTRY CONFIGURATIONS for (UL/CSA) 
Petroleum Refining:
MX6-KJ53R211MX6 - LEL, CO/H2S, O2, SO2, PID, Ext. Li-ion, Pump
Brewing/Bottling/Wineries:
MX6-K103Q211MX6 - LEL, CO, O2, CO2, Ext. Li-ion, Pump
Pulp/Paper:
MX6-KJ835101MX6 - LEL, CO/H2S, O2, SO2, ClO2, Li-ion
HazMat:
MX6-K673R211MX6 - LEL, O2, NH3, Cl2, PID, Ext. Li-ion, Pump
Mining:
MX6-M1030401MX6 - CH4 (%), CO, O2, Li-ion (MSHA/AUS)
Mining (Diesel Applications):
MX6-M1D34401MX6 - CH4 (%), CO, O2, NO2, NO, Li-ion Ext.

  1. MX6 Docking and Calibration Stations

     
    Part Number Description
    18106724-ABC+
    DS2 Docking Station™ for MX6
     
     

    + DS2 Docking Station Ordering Information
    A = Wireless Option (currently unavailable) 0 - none
    B = Number of iGas Readers at $49.50each
    C = Power Cord Option
      0 - US 1 - UK 2 - EU 3 - AUS
      4 - ITA 5 - DEN 6 - SWZ  
  2. MX6 Remote Sampling and Confined Space Kit

     
    Part Number Description
    MX6 Confined Space Kits Click for Details MX6 Confined Space Kits
    SP6 Motorized Sampling Pump
    18106765
    SP6 Motorized Sampling Pump
    Calibration Tubing Assembly with Integrated "T" Fitting
    17116096
    Calibration Tubing Assembly with Integrated "T" Fitting (For use when calibrating a monitor with pump using a positive flow regulator)

  3. MX6 iBrid™ Carrying Cases 

    Part Number Description
    MX6 Hard Leather Carrying Case, Diffusion - Low Res
    18106856-0
    Hard Leather Carrying Case, Diffusion
    MX6 Diffusion Hard Leather Case Without Window
    18106856-1
    Hard Leather Carrying Case, Diffusion, Without Window
    Hard Leather Case for MX6 without pump - Low Res
    18106880-0
    Hard Leather Carrying Case, Aspirated 
    Leather Case for Diffusion MX6 - Low Res
    18106880-1
    Hard Leather Carrying Case, Aspirated, Without Window
  4. MX6 iBrid™ Chargers and Batteries

     
    Part Number Description
    Battery Charger, 12V
    18107011
    Battery Charger, 12V
    MX6 Battery Charger, 5-Unit
    18107136
    Battery Charger, 5-Unit
      18107250 MX6 Truck Mount Charger, Hard-wired
      18107243 MX6 Truck Mount Charger, 12V
    Rechargeable Li-ion Battery Pack, UL/CSA/ATEX
    17131038-1
    Rechargeable Li-ion Battery Pack, UL/CSA/ATEX
    Rechargeable Li-ion Ext. Battery Pack, UL/CSA/ATEX
    17131038-2
    Rechargeable Li-ion Ext. Battery Pack, UL/CSA/ATEX
    Rechargeable Li-ion Battery Pack, MSHA/AUS
    17131038-4
    Rechargeable Li-ion Battery Pack, MSHA/AUS
    Rechargeable Li-ion Ext. Battery Pack, MSHA/AUS
    17131038-5
    Rechargeable Li-ion Ext. Battery Pack, MSHA/AUS
    Alkaline Battery Pack, UL/CSA/ATEX
    17131046-3
    Alkaline Battery Pack, UL/CSA/ATEX
    Alkaline Battery Pack, MSHA/AUS
    17131046-6
    Alkaline Battery Pack, MSHA/AUS
  5. MX6 iBrid™ Sensors

    Part Number Description
    17124975-1 Carbon Monoxide (CO)
    17124975-2 Hydrogen Sulfide (H2S)
    17124975-3 Oxygen (O2)
    17124975-4 Nitrogen Dioxide (NO2)
    17124975-5 Sulfur Dioxide (SO2)
    17124975-6 Ammonia (NH3)
    17124975-7 Chlorine (CI2)
    17124975-8 Chlorine Dioxide (CIO2)
    17124975-9 Phosphine (PH3)
    17124975-A Hydrogen Chloride (HCI)
    17124975-B Hydrogen Cyanide (HCN)
    17124975-C Hydrogen (H2)
    17124975-D Nitric Oxide (NO)
    17124975-E  Phosphine (PH3) (high) 
    17124975-G Carbon Monoxide (H2 low)
    17124975-H Carbon Monoxide (high)
    17124975-J Carbon Monoxide / Hydrogen Sulfide (CO/H2S)
    17124975-K %LEL (Pentane)
    17124975-L %LEL (Methane)
    17124975-M Methane (0-5% volume)
    17124975-N Methane IR (0-100% volume)
    17124975-P Hydrocarbons IR (0-100% LEL)
    17124975-Q Carbon Dioxide IR (0-5% volume)
    17124975-R PID (VOCs)
    17124975-S Methane (0-100% LEL)

Type of Help:

First Name:

Last Name:

Company:

Postal Code:

Country:

Email:

Phone:

Contact Me About Portable Detectors