mobile menu close icon mobile menu icon

CONFIGURAÇÕES DE ALARME DOS DETECTORES DE GÁS

GÁS

BAIXO

ALTO

TWA

STEL

O2 19,5% vol 23,5% vol N/A N/A
CO 35 ppma, b 70 ppmb 35 ppma  200 ppm
H2S 10 ppm 20 ppm 10 ppm 15 ppm
SO2 2,0 ppm 4,0 ppm 2,0 ppm 5,0 ppm
NO2 3,0 ppm 6,0 ppmc 3,0 ppm 5,0 ppm
Cl2 0,5 ppm 1,0 ppm 0,5 ppm 1,0 ppm
ClO2 0,1 ppm 0,2 ppm 0,1 ppm 0,3 ppm
CO2 0,5% vol 1,0% vol 0,5% vol 3,0% vol
PH3 0,3 ppm 0,6 ppm 0,3 ppm 1,0 ppm
NH3 25 ppm 50 ppm 25 ppm 35 ppm
HCN 5,0 ppm 10,0 ppm 4,0 ppm 4,0 ppm
NO 25 ppm 50 ppm 25 ppm 25 ppm
HCl 2,5 ppm 5,0 ppm 2,5 ppm 2,5 ppm
H2 50 ppm 100 ppm N/A N/A
CH4 1,0% vol 1,5% vol N/A N/A
LEL 10% LEL 20% LEL N/A N/A
PID 100 ppm 200 ppm N/A N/A

Nota:
a. Para CO, o PEL OSHA é de 50 ppm. A Industrial Scientific usa a norma de ajuste de 1989 (35 ppm). Todos os pontos de ajuste de alarme são configuráveis em campo em toda a faixa do sensor. Exceções: LEL/CH4 - 0 a 60% e 0 a 3,0% por volume CH4. Havendo padrões, todas as configurações de alarme são baseadas no seguinte: os alarmes baixos são baseados nos valores PEL OSHA e/ou NIOSH; os alarmes altos são baseados em 2 vezes os valores PEL OSHA.

b. Os limites MSHA para CO são 50 ppm para um alarme baixo e 100 ppm para um alarme alto.

c. Os limites MSHA para NO2 são 5 ppm para um alarme alto.