You wouldn’t drive a vehicle without putting on your seat belt. You wouldn’t ride a bike without putting on a helmet. You don’t go to bed at night without locking your doors. Everyday practices like these create good habits that make our lives easier and safer. When it comes to gas detection, safe and simple practices like these are no different. Gas detectors that are used every day require the same type of attention. You may not think much about putting on a seat belt in a vehicle, but it sure does help when you need it. You may also not think much about bump testing a gas detector, but it sure does help to know that your gas detector works when you need it most.

What is a bump test?

Bump testing is the only way to ensure proper sensor and alarm functionality. A bump test is defined as the process of briefly exposing sensors in a gas detector to an expected concentration of gas that is greater than the alarm set points. The purpose of the bump test is to check for sensor and alarm functionality. However, it does not check for accuracy. It is important to note that accuracy is ensured through calibration, which is a completely different process than bump testing.

 

Think of bump testing a gas detector like using a flashlight. What’s the first thing everyone does when they pick up a flashlight? They try turning it on to see if it works! If the flashlight does not turn on, you know that you either need a new bulb, a new battery, or a new flashlight, because the one you have cannot help you. Gas detectors are no different. The first thing you should do before using your gas detector is to make sure it works. Without a bump test, how do you know that the gas detector you have can perform the way you need it to? Applying gas to the sensors in a detector is just like checking to see if your flashlight works. If the bump test fails, you know that troubleshooting or further maintenance is required.

Why is bump testing important?

Gas detectors are made to survive harsh environments. They are often dropped, exposed to extreme temperatures, humidity, moisture, dust, mud, and sludge. Any of these can factor into a gas detector’s performance. Sensors can become dislodged if a monitor is dropped. Filters can become clogged from moisture or dust. Enough mud or sludge can completely block a sensor from seeing gas. Because of these factors, manufacturers recommend bump testing gas detectors before each day’s use. You may not realize it, but all of these factors that occur during day-to-day use can impact a gas detector’s performance.

How does bump testing work?

For toxic and combustible sensors, the typical output in clean air is zero, whether reading in parts per million (PPM), percent of lower explosive limit (LEL), or percent by volume. One main exception to this is an oxygen sensor, which should read around 20.9% volume in ambient air when functioning. So bump testing a standard four-gas instrument will drive the gas readings up on your toxic and combustible sensors, while driving the reading for the oxygen sensor down.

The problem is that toxic and combustible sensors will generally read zero in an ambient environment whether they are functioning or not. Therefore, the only way to know if they will respond to gas is by, you guessed it, exposing them to gas.

How can I bump test my instrument?

bump testing

Bump-N-Go cylinders are designed to simplify bump testing for mobile workers or those who do not have access to a docking station. The miniature cylinders are only 3.8 inches (97 mm) tall and provide up to 250 bump tests when using the corresponding pushbutton regulator. The cylinders have a one-year shelf life and are available for single-gas CO and H2S instruments as well as standard 4-gas (CO, H2S, O2, LEL) instruments.

Because of the broad range of gas detector applications, manufacturers have come up with many different ways to perform bump tests. The easiest and usually most efficient way to bump test is by using docking stations, which are often connected to web-based gas detection management software. Through this software, users can schedule bump tests to occur every day. If a failure occurs, the software can notify the user or safety manager of the failure, so they know that further action is needed. Docking stations draw gas through a connected cylinder, and then apply that gas to the detector that is docked. The stations are designed to resemble a manual bump test.

Manual bump tests are performed simply by using a gas bottle, a regulator, tubing, a calibration cup (if using a diffusion instrument), and a gas detector. Users can put the instrument into bump test mode, then apply the gas. The gas detector will either cycle through each individual sensor or do them all at once, depending on instrument settings. After the test is complete, the instrument will display results, showing whether it was a passed or failed test. Alternatively, users can perform a manual bump test simply by applying gas to the instrument while it is on its main gas reading screen. If each sensor shows readings in response to the gas and the detector goes into alarm, then that instrument is good to go.

What are the challenges of bump testing?

The need for bump testing can create some challenges. The number of instruments a company has, the applications, and locations of equipment can all come into play. For this reason, gas cylinders come in a variety of sizes. Users may need larger cylinders to connect to docking stations that are used every day. Users may also need smaller, more portable cylinders to bump test instruments when workers are on the go. Luckily for users, there is a wide array of cylinders available to fit the right application. Cylinders come in all shapes and sizes, and come in specific gas blends available for all types of sensors.

Another challenge of bump testing is the training aspect. It is often difficult for safety managers to find time to train users, and workers often do not have time to train one another. Luckily, gas detection companies offer a wide array of training resources available to end users. Trainers can travel to customer locations for on-site training to give a more hands-on approach. Alternatively, gas detection companies post videos, informational pieces, articles, and many other resources for end users to utilize to meet their needs.

The bottom line

The bottom line is that bump testing saves lives. Users should never risk using a gas detector without checking to make sure it is functioning. With the right training, understanding, and repetition, bump testing a gas detector can become as routine as putting on a seat belt when you get into your car. It is just as important, so why not start now?