Exceptional configuration
The MX 2100 multigas detector features a unique configuration allowing 4 measuring positions as standard for measuring 6 different parameters.The MX 2100 adapts to the needs of your activity, providing the following detection combinations :
• 3 channels: toxic gases, CO2, O2
• 1 channel for explosive gases
Universal explosimetry reading
Fitted with a sensor specifically designed for measuring most common explosive gases on a scale of 0 to 100 % LEL, the MX 2100 is practically a universal explosimeter. The MX 2100 also has a library of 32 pre-programmed gases for measurement of a dedicated gas.
Choice of toxic gas and oxygen measurement
With the possibility of changing sensor blocks without adjustment you can choose from a large selection of sensors and use 4 of them simultaneously (with the CO/H2S option). This feature makes the MX 2100 a genuine portable analysis laboratory.
Conformity with the ATEX Directive
The MX 2100 meets all the new requirements of the ATEX Directive 94/9/EC giving it a very high safety level. This Category 1 device can be operated in zone 0 and with any gas or vapour concentration. This special feature taken with its other characteristics makes it the best performing device on the market.
Total work environment monitoring
Graphical display
The LCD display unit features automatic back-lighting for alarms or faults. Its is a graphical display for easier measurement readout.
• Measurement display :
– display of 5 measurements with units and type of gas*
– warning if any channel needs to be calibrated
• Parameter display :
– date and time
– min. - max. (resettable)
– STEL and TWA
– remaining run time (bar graph)
Warning lights
A set of warning lights on the top of the unit displays alarms in all directions and in any work environment.
Review
The MX 2100 can be used to print a review of all events and measurements carried out. The variable storage interval can be set by the user who has the possibility of storing up to 200,000 records**.
Work environment monitoring can be adapted to suit the activity.The safety manager and user have all the advantages of a highlydeveloped management tool.
Alarms
• Gas alarms :
– text messages for each channel on the display unit
– flashing light signal common to all channels
– audible signal
– alarm acknowledgement compliant with safety rules
• Alarm levels :
– 2 instantaneous thresholds per channel in EXPLO and TOX modes
– STEL/TWA in TOX mode
– running average over 15 minutes and 8 hours
– high and low thresholds (2 low thresholds as option) and 1 threshold for the catharometric channel
Trouble alarms
• Continuous luminous and audible signal common to all channels :
– 20 % over alarm in negative mode
– 120 % over alarm in TOX and oxygen mode
– 100 % over alarm in EXPLO mode
User-friendliness
• At a single press of a tactile pad the MX 2100 runs selfdiagnostics and indicates any anomalies; it continuously analyses the gases for which it has been programmed. Auto-zero is possible on demand or as a charger output (option). A quick operation allows the user to change the gas to be detected. The data-logging function allows storage of events and measurements with variable storage interval. Multi-user location identification is available with 32 texts of 16 characters.
• COM 2100 software is used to supervise and maintain the device :
– text display of measurements and channel parameters
– troubleshooting if there is a problem
– intuitive programming of the detector and measurement channels
– option management
– channel calibration via automated drop-down menu
– printout of encrypted status sheet and test sheet
– management, display and printout of stored events and measurements
– protection by password
• The MX 2100 can be linked to a PC via an infrared port for use on a suitably equipped computer. An adaptor module is available for other computers.