iTrans
• O2, toxic or combustible gas detector
• Dual sensor platform (on-board & remote placement)
• Split-screen LED display
• 4-20 mA and ModBus RTU output
iTrans
>>Overview>>Features & Benefits>>Specifications>>Ordering Information>>Accessories>>DocumentsCl2, ClO2, CO, CO/H2 null, H2, H2S, HCl, HCN, LEL, NO2, NO, NH3, O2, PH3, SO2
The iTrans fixed-point gas monitor employs an intelligent electronics platform to provide one or two points of detection from a single head for maximum flexibility, superior performance and lower installation costs.
Able to monitor any combination of gases for a specific environment, iTrans utilizes our industry-proven “smart” sensor technology and safety features including automatic sensor recognition, access code security, and zero and cal fault protection – all enclosed within an explosion-proof aluminum or stainless steel housing.
The microprocessor-controlled transmitters are capable of independent operation or multi-point system configuration. With optional on-board relays, the monitor has the added ability of stand-alone operation, activating alarms, horns, or fans and can also shut down a system without the need to wire back to a central control panel.
Enclosure: |
Cast aluminum, poly-bonded coating. Explosion-proof, NEMA 4X, IP66 rated
|
Sensors: |
Combustible Gases: Catalytic bead and/or Non-Dispersive Infrared (NDIR) Oxygen/Toxic Gases: Electrochemical diffusion |
Ranges: |
| Gas |
Symbol |
Range |
Increments |
| Combustible gases |
LEL |
0 to 100% LEL |
1% |
| Hydrogen |
H2 |
0 to 999 ppm |
1 ppm |
| Oxygen |
O2 |
0 to 30.0% of volume |
0.1% |
| Ammonia |
NH3 |
0 to 200 ppm |
1 ppm |
| Carbon Monoxide |
CO |
0 to 999 ppm |
1 ppm |
| Hydrogen Sulfide |
H2S |
0 to 500 ppm |
1 ppm |
| Sulfur Dioxide |
SO2 |
0.2 to 99.9 ppm |
0.1 ppm |
| Hydrogen Cyanide |
HCN |
0.2 to 30 ppm |
0.1 ppm |
| Hydrogen Chloride |
HCL |
0.2 to 30 ppm |
0.1 ppm |
| Phosphine |
PH3 |
0 to 1 ppm |
0.01 ppm |
| Nitrogen Dioxide |
NO2 |
0.2 to 99.9 ppm |
0.1 ppm |
| Nitric Oxide |
NO |
0 to 999 ppm |
1 ppm |
| Chlorine |
Cl2 |
0.2 to 99.9 ppm |
0.1 ppm |
| Chlorine Dioxide |
ClO2 |
0.02 to 2 ppm |
0.01 ppm |
|
Display: |
Dual-channel split-screen LED display (4 digit, 7 segment arrangement per channel) provides simultaneous display of one or two gases. |
Input Voltage: |
12-28 VDC operating range (24 VDC typical) |
Input Current (max.): |
Toxic Gas/Oxygen: 150 mA @ 24 VDC (single gas) Combustible gases (Catalytic): 175 ma @ 24 VDC, 0.6 A peak (single gas) Combustible gases (Infrared): 150 ma @ 24 VDC, 0.6 A peak (single gas) Combined catalytic/infrared: 280 ma @ 24 VDC (two gas)
|
Signal Output: |
4-20 ma, (linear analog) and ModBus RTU (digital) RS485 digital communication with ModBus RTU software protocol system at 9600 baud. Three or four wire system capable of accommodating over 200 devices in bus configuration. Address selection through on-board 8-position dipswitch. |
Alarm Relays: |
3 alarm relays: Two user-programmable relays, SPST, N.O.; plus one fault relay, SPST, N.C. |
Contact Capacity: |
5 Amps @ 30 VDC |
Temperature Range: |
-20°C to 50°C (-4°F to 122°F), typical |
Humidity Range:
|
15-90% RH (non-condensing), typical |
Approvals: (sensor-specific) |
NRTL/c and CSA: Class I, Div. 1, 2, Groups B, C, D; AEx d IIB + H2 ATEX: Ex d IIB + H2 T5 (sensor-specific) IEC: Ex d IIB + H2 T5 (sensor-specific) China: GB 3836.1-Ex d IIC T4; LEL version GB15322-94 Fire protection
Consult factory for current approval status
|
iTrans™ offers a wide variety of sensor configurations and relay options for maximum flexibility and affordability. Use the following guide to select the options that best fit your monitoring needs and applications. Industrial Scientific recommends that a fixed system application survey be completed to help provide the most accurate assessment of your equipment requirements.
iTrans™ Base part number: 7814635 ABCDEFG + sensor options as listed below. Dual reading LED display, magnetic calibration tool and calibration cup are standard items with all iTrans monitors. |
|
|
|
Ordering Example: An iTransTM with an on-board LEL (4-20 mA scale 0-100) and remote mount H2S (4-20 mA scale 0-500) with optional relays would have a part number of 7814635-1C21241 |
|
A - Sensor 1 Configuration
|
|
E - Sensor 2 Configuration |
0 = No Sensors |
|
0 = No Sensors |
1 = Explosion Proof / On-Board |
|
1 = Explosion Proof / On-Board |
2 = Explosion Proof / Remote (max. distance = 200m) |
|
2 = Explosion Proof / Remote (max. distance = 200m) |
3 = Non-Hazardous Remote / Duct Mount |
|
3 = Non-Hazardous Remote / Duct Mount |
4 = Explosion Proof / On-Board with Splash Guard |
|
4 = Explosion Proof / On-Board with Splash Guard |
5 = Explosion Proof / Remote with Splash Guard
(max. distance = 200m) |
|
5 = Explosion Proof / Remote with Splash Guard
(max. distance = 200m) |
|
|
|
B - Gas Sensor 1
|
|
F - Gas Sensor 2 |
1 = Carbon Monoxide (CO) |
|
1 = Carbon Monoxide (CO) |
2 = Nitric Oxide (NO) |
|
2 = Nitric Oxide (NO) |
3 = Ammonia (NH3) |
|
3 = Ammonia (NH3) |
4 = Hydrogen Sulfide (H2S) |
|
4 = Hydrogen Sulfide (H2S) |
5 = Sulfur Dioxide (SO2) |
|
5 = Sulfur Dioxide (SO2) |
6 = Nitrogen Dioxide (NO2) |
|
6 = Nitrogen Dioxide (NO2) |
7 = Chlorine (Cl2) |
|
7 = Chlorine (Cl2) |
8 = Chlorine Dioxide (ClO2) |
|
8 = Chlorine Dioxide (ClO2) |
9 = Hydrogen Cyanide (HCN) |
|
9 = Hydrogen Cyanide (HCN) |
A = Oxygen (O2) |
|
A = Oxygen (O2) |
B = LEL Infrared (factory Methane calibration) |
|
B = LEL Infrared (factory Methane calibration) |
C = LEL Catalytic Plug-In (factory Pentane calibration) |
|
C = LEL Catalytic Plug-In (factory Pentane calibration) |
D = Carbon Monoxide - Hydrogen Null (CO - H2) |
|
D = Carbon Monoxide - Hydrogen Null (CO - H2) |
F = Hydrogen Chloride (HCl) |
|
F = Hydrogen Chloride (HCl) |
G = LEL Infrared Propane |
|
G = LEL Infrared Propane |
K = Phosphine (PH3) |
|
K = Phosphine (PH3) |
L = Hydrogen (H2) |
|
L = Hydrogen (H2) |
|
|
|
C - 4-20 ma Output Scale for Sensor 1
|
|
G - 4-20 ma Output Scale for Sensor 2 |
0 = 0 - 999 |
|
0 = 0 - 999 |
1 = 0 - 500 |
|
1 = 0 - 500 |
2 = 0 - 100 |
|
2 = 0 - 100 |
3 = 0 - 50 |
|
3 = 0 - 50 |
4 = 0 - 30 |
|
4 = 0 - 30 |
5 = 0 - 10 |
|
5 = 0 - 10 |
6 = 0 - 2 |
|
6 = 0 - 2 |
7 = 0 - 1 |
|
7 = 0 - 1 |
8 = 0 - 20 |
|
8 = 0 - 20 |
9 = 0 - 200 |
|
9 = 0 - 200 |
|
|
|
D - Optional On-Board Relays
|
|
|
0 = No Relay Module |
|
|
1 = With On-Board Relays |
|
|
|
|
|
|
Common Configurations |
Part Number |
|
Description |
7814635-1G000 |
|
iTransTM, On-Board IR LEL, No Relays |
7814635-11010 |
|
iTransTM, On-Board CO, With Relays |
7814635-13110 |
|
iTransTM, On-Board NH3, With Relays |
7814635-1G201A4 |
|
iTransTM Dual Unit, On-Board IR LEL and O2, No Relays |
7814635-23202C2 |
|
iTransTM Dual Unit, Remote NH3 and Remote LEL Catalytic, No Relays |
|
|
|
iTrans Documents
Literature
Manuals
Product Notices
>> visit this product's information page
Remote Alarms / Alarm Modules |
| Part Number |
Description |
|
| 77016632 |
24 VDC Audio/Visual Alarm Red Lens |
|
| 77016640 |
24 VDC Audio/Visual Alarm Amber Lens |
|
| 77016657 |
24 VDC Audio/Visual Alarm Clear Lens |
|
| 68100296 |
Alarm Indicating Station, 24 VAC Audio/Visual Alarm |
|
| 68100304 |
Alarm Indicating Station, 24 VDC Audio/Visual Alarm |
|
| 68100312 |
Alarm Indicating Station, 120 VAC Audio/Visual Alarm |
|
| 78100112 |
120 VAC Visual Remote Alarm
|
|
| 78100138 |
24 VDC Visual Remote Alarm |
|
| 78100146 |
120 VAC Audio Remote Alarm w/o Silence Switch |
|
| 78100161 |
24 VDC Audio Remote Alarm w/o Silence Switch |
|
| 78100054 |
120 VAC Audio/Visual Remote Alarm w/ Silence Switch |
|
| 78100070 |
24 VDC Audio/Visual Remote Alarm w/ Silence Switch |
|
| 77016814 |
12 / 24 VDC Banshee Alarm |
|
| |
|
|
iTrans Replacement Sensors |
| Part Number |
Description |
|
| 77024453 |
Ammonia Sensor |
|
| 77024438 |
Carbon Monoxide Sensor |
|
| 77024479 |
Chlorine Sensor |
|
| 77024511 |
Chlorine Dioxide Sensor |
|
| 77024446 |
Hydrogen Sensor (ppm) |
|
| 77024461 |
Hydrogen Chloride Sensor |
|
| 77025898 |
Hydrogen Cyanide Sensor |
|
| 77024420 |
Hydrogen Sulfide Sensor |
|
| 77024404 |
LEL Catalytic Sensor |
|
| 77024487 |
Nitric Oxide Sensor |
|
| 77024495 |
Nitrogen Dioxide Sensor |
|
| 77024412 |
Oxygen Sensor |
|
| 77025872 |
Phosphine Sensor |
|
| 77024503 |
Sulfur Dioxide Sensor |
|
| 77027944 |
Carbon Monoxide (H2 Null) |
|
| |
|
|
Power Supplies |
| Part Number |
Description |
|
| 78101151 |
Model 6510 Power Supply Standard 110 VAC to 24 VDC, 50 W output |
|
| 78101169 |
Model 6565 140 W Offline-type UPS w/ Internal 24 VDC, 50 W output |
|
| 78101581 |
Model 6580 400 W / 800 W Peak Battery Backup System, Expandable offline-type UPS, 110 VAC, w/ modified sine wave output |
|
| |
|
|
Mounting Kits |
| Part Number |
Description |
|
| 78104312-STND |
Duct Mount Kit for iTrans Catalytic/Toxic/Oxygen |
|
| 78104312-IR |
Duct Mount Kit for iTrans Infrared
|
|
| |
|
|
Remote Sampling Pumps |
| Part Number |
Description |
|
| 78104130 |
Remote Sample Pump 24 VDC Operation |
|
| 78104122 |
Remote Sample Pump 120 VAC Operation |
|
| |
|
|
Accessories |
| Part Number |
Description |
|
| 77015741 |
Calibration Cup for Infrared Sensor |
|
| 77014579 |
By-Pass/Flow-thru Kit (not for infrared sensor) |
|
| 77015303 |
Splash Guard/Remote Cal Cup for Toxic, O2 and LEL |
|
| 77018083 |
Replacement Filter for 77015303 |
|
| 77020063 |
Splash Guard/Remote Cal Cup for Infrared Sensor |
|
| 77019644 |
Replacement Filter for 77020063 |
|
| 77024065 |
iTransTM Calibration Wand |
|
| 77023588 |
iTransTM Splash Guard |
|
| 77023513 |
iTransTM Calibration Cup |
|
| |
|
|
Feature |
Benefit |
Single or dual channel configuration |
Flexible platform allows for any combination of sensors. Lower price point per channel for monitoring more than one gas in an area. |
ModBus RTU interface |
Allows system integrators to connect iTrans to SCADA, HMI, and PLC systems. |
Remote sensors |
Sensors are designed to be mounted remotely from the iTrans head (up to 200 meters away) or in a stand-alone fashion (in ModBus applications). |
Non-intrusive calibration |
Allows field calibration in hazardous locations. |
LED display |
Large, bright display that can be seen from across plant; easy to read in dark environments. |
On-board relays |
Enables user to activate alarms, horns, fans, locally without the need for a controller. |
Low-cost |
Extremely low price per point of detection |
Push button/keypad operation |
Intuitive, easy-to-use interface makes it simple to program alarms, set relays, zero, calibrate, and change span gas settings. |
Field upgradable “smart” sensors |
Second sensor can be added at any time in the field. Sensor type can also be changed in the field. |
Programmable alarms |
Programmable low and high alarms for each channel; flashing alarm message on LED display activates to indicate hazardous conditions. |
|
|