M-Cal Calibration Station
• Stand-alone operation. No PC is required.
• Calibration & function (bump) testing
• Battery recharging
• Simple, two-button operation
With the M•Cal™ Calibration Station, calibrating, bump testing and charging the M40 Multi-Gas Monitor has never been easier or more cost-effective. Available in single- or six-unit versions, the M•Cal will accommodate all M40 monitors with software version 4.0 or higher in a diffusion mode or with an SP40 sampling pump attached. The M•Cal features simple, two-button operation allowing the user to quickly and easily calibrate or function (bump) test the instrument, and the LED indicators display whether or not the instrument passed or failed the desired function.
A PC is not required to operate this stand-alone system, making the unit extremely portable and flexible. Available accessories include an optional battery powered kit that enables the system to be used in remote areas, and a serial data printer that automatically prints calibration and bump test reports. The reports can be used for confined space entry permits with information pertaining to instrument serial numbers, pass/fail indications, bump test readings and full span readings for each sensor installed in the M40 monitor.
Monitors Supported:
|
M40 Software versions 4.0 and higher |
Configurations:
|
M40 only version
M40/SP40 pump version
Six-unit versions (all configurations)
|
Dimensions M•Cal401:
|
4.03" x 6" x 7" (10.24 cm x 15.24 cm x 17.78 cm)
|
Dimensions M•Cal406:
|
4.92" x 12.23" x 13" (12.5 cm x 31.06 cm x 33.02 cm) |
Gas Inlets:
|
One fresh air, one gas cylinder
|
Pump Flow Rate:
|
0.25 LPM |
Input:
|
Universal power supply |
Communiation:
|
On-board LEDs give status indication (pass, fail, charging). Real-time readings on M40 display during calibration.
|
Internal Memory:
|
Stores up to 150 bump test and calibration reports before overwrite. Reports contain serial number, time, date, sensor information, pass/fail, span values and bump values (for bump tests). Memory will retain information when power is off.
|
Part Number |
Description |
Price* |
18105965-10X+ |
M•Cal401 – Single-unit, M40 bay |
$874.50 |
18105965-01X+ |
M•Cal401 – Single-unit, M40/SP40 bay |
|
18105973-06X+ |
M•Cal406 – Six-unit, with six M40/SP40 bays |
$1,754.50 |
18105973-15X+ |
M•Cal406 – Six-unit, with one M40 bay and five M40/SP40 bays |
$1,754.50 |
18105973-24X+ |
M•Cal406 – Six-unit, with two M40 and four M40/SP40 bays |
$1,754.50 |
18105973-33X+ |
M•Cal406 – Six-unit, with three M40 and three M40/SP40 bays |
$1,754.50 |
18105973-42X+ |
M•Cal406 – Six-unit, with four M40 and two M40/SP40 bays |
$1,754.50 |
18105973-51X+ |
M•Cal406 – Six-unit, with five M40 bays and one M40/SP40 bay |
$1,754.50 |
18105973-60X+ |
M•Cal406 – Six-unit, with six M40 bays |
$1,754.50 |
|
|
|
+M•Cal™ Calibration Station Ordering Information – X = Power Cord (0 = N. Amer., 1 = U.K., 2 = Eur, 3 = AUS) |
|
|
|
|
|
|
Part Number |
Description |
Price* |
17117722 |
Serial data dot matrix printer – 120-230 VAC |
$527.90 |
17119843 |
Replacement cable for M•Cal to PC interface 6' Null Modem F/F |
$7.65 |
17118118 |
Replacement power supply |
$66.00 |
M40-KIT-DFR0000 |
M•Cal accessory kit (demand flow regulator, calibration gas cylinder, tubing, CD) |
$671.00 |
18102509 |
Demand flow regulator |
$374.00 |
18102187 |
Calibration/ Bump Gas, 58L (100 PPM CO, 25 PPM H2S, 25% LEL pentane, O2) |
$278.30 |
18102242 |
Calibration/ Bump Gas, 58L (100 PPM CO, 25 PPM H2S, 50% LEL methane, O2) |
|
17124348 |
Wall/ Desk Mount Cylinder Holder |
$45.40 |
|
|
|
|
|
|
*Note: Prices shown do not include freight, currency exchange rates, duty, brokerage, or insurance.
|
M-Cal Calibration Station Documents
Literature
Manuals
Feature |
Benefit |
Two button operation |
Simple and easy use. One button initiates bump tests, the other initiate calibrations. |
|
|
Automatically bumps, calibrates, and charges the M40. |
Quick and simple way to manage and maintain M40 instruments with software versions 4.0 and higher. |
|
|
Stand alone unit |
No PC is required to operate the M•Cal™. This allows it to be completely portable and independent. |
|
|
Single and Six unit versions |
Completely scalable to accommodate both small and large customers |
|
|
Dedicated M40/SP40 versions available |
Allows users to automatically calibrate or bump test M40s that have SP40s attached, without removing the pump. |
|
|
Bump and Calibration reports |
The M•Cal™ automatically generates bump and calibration reports after each task is completed. These reports will be automatically printed on an optional serial printer when attached. |
|
|
Reports |
Allows for easy record keeping of bumps/calibrations for permits. |
|
|
LED indications |
Gives user status indication of passed or failed bump tests or calibrations. |
|
|
Cost |
Most features of any calibration station for the price. Six-unit version is the lowest cost multi-unit solution available. |
|
|
Small Size
– 4.03 x 6 x 7 (Single Unit)
– 4.92 x 12.23 x 13 (Six Unit) |
Makes the M•Cal™ portable |
|
|